QIYUE FAN manufactures industrial centrifugal fans for ventilation, air exhaust, forced draft, induced draft, dust handling, combustion air, and process air systems. Our centrifugal fan range covers different airflow and pressure requirements, with configurations selected according to the operating medium, temperature, dust load, installation conditions, and drive requirements.


From standard fan series to application-specific configurations, we provide fan selection and technical support based on your actual operating point.

 

 
  • High Pressure Centrifugal Fans
    High pressure centrifugal fans are designed for applications requiring controlled airflow and high system pressure. They are used for forced draft, process air supply, combustion air, dust...
    read more
 

Centrifugal Fan Product Series

 

General & Industrial Ventilation Series

 
01
 

4-68 Series General Ventilation Fans

Engineered for broad air movement across factories, warehouses, and industrial facilities, supporting multiple drive arrangements (A, C, D, and B).

 
02
 

4-72 Series General Ventilation Fans:

Designed for clean air handling, commercial HVAC duct networks, and industrial supply systems with low to medium system resistance.

 
03
 

4-79 Series Backward-Curved Fans:

Built for indoor air supply, warehouse extraction, and equipment rooms requiring higher pressure capability and lower operating sound levels.

High Pressure Centrifugal Fans

 

High-Pressure & Heavy-Duty Process Series
 

General & Industrial Ventilation Series

4-68 Series: Built for factory and warehouse air turnover, supporting flexible drive layouts (A/C/D/B) to adapt to varied site footprints.
4-72 Series: The baseline choice for standard industrial supply and exhaust ducts handling clean air under low-to-medium resistance.
4-79 Series: Designed with backward-curved impellers to deliver higher static pressures with reduced acoustic impact in large indoor spaces.

High-Pressure & Heavy-Duty Process Series

8-09 Series: Purpose-built for targeted high-pressure blowing, combustion air injection, and furnace supply duties.
9-12 Series: Focused on overcoming severe friction losses across extended duct runs, dense filter banks, and process vessels.
9-19 Series: A pressure-first series engineered for burner air feeds, pneumatic conveying, and cyclone system discharge.
9-26 Series: Combines high static pressure with substantial volumetric airflow to sustain continuous process loads without motor stalling.
10-16 Series: Reinforced structural build intended for dense-phase pneumatic handling, extreme pressure furnace draft, and heavy chemical process loops.

 

Impeller Options for Different Operating Conditions

 

Impeller Type

Main Characteristic

Typical Duty

Backward-Curved

Efficient operation and stable power characteristics

Clean air and higher-resistance systems

Forward-Curved

High airflow at lower speed

Compact, lower-pressure ventilation

Radial Blade

Better suited to particulate-laden air

Dust, particles, or material handling

 

Drive Arrangements

 

Drive

Main Difference

Typical Selection Consideration

Direct Drive

Compact, fewer transmission components

Standard temperature and fixed-speed applications

Belt Drive

Speed can be adjusted through pulley selection

Variable speed or motor isolation requirements

Coupling Drive

Suitable for larger/heavier-duty arrangements

High-power continuous industrial operation

 

Centrifugal Fan Series Comparison

 

Series

Primary Duty

Pressure Level

Airflow Demand

Typical Applications

System Condition

4-68

General ventilation

Low–Medium

General to continuous airflow

Factories, workshops, warehouses, large indoor spaces

Low–medium resistance

4-72

General-purpose ventilation

Low–Medium

General airflow

Workshop ventilation, equipment exhaust, ducted air supply

Low–medium resistance

4-79

Higher-resistance ventilation

Medium

Medium–high airflow

Factories, warehouses, machinery rooms, process ventilation

Higher system resistance

8-09

High-pressure blowing

High

Application dependent

Furnace and process air

High-pressure duty

9-12

High-resistance air delivery

High

Application dependent

Long ducts, equipment air delivery

High system resistance

9-19

High-pressure blowing

High

Application dependent

Forced air, burner air supply, pneumatic conveying

High-pressure / conveying duty

9-26

Heavy-duty high-pressure

High

Application dependent

Heavy-duty air systems, industrial processes

High differential pressure

10-16

Heavy-duty high-pressure

High

Application dependent

Furnace, process air, conveying

High-pressure, demanding mechanical duty

 

 
Manufacturing and Quality Standards
 
01/

Dynamic Balancing: Impellers are dynamically balanced in accordance with ISO 1940 Grade G2.5 standards to control operational vibration.

02/

Weld Inspection: Non-destructive testing, including ultrasonic and dye-penetrant inspection, is applied to structural welds and hub connections based on project specifications.

03/

Thermal Management: High-temperature fan configurations can incorporate shaft cooling, bearing protection, and heat-resistant materials according to the operating temperature and fan arrangement.

04/

Factory Testing: Mechanical run tests are conducted before shipment to verify vibration velocity, bearing temperature rise, and current draw.

 

Management Systems & Compliance Scope
 

Certified Management Systems: Manufacturing operations comply with ISO 9001, ISO 14001, and ISO 45001 management standards.


Third-Party Factory Audit: Shandong Qiyue Fan Co., Ltd. has undergone independent on-site audit verification by TÜV Rheinland, verifying site existence and business operations.


EAEU Project Compliance: Holds a registered EAEU Declaration of Conformity under TR CU 010/2011 (Machinery Safety) and TR CU 020/2011 (EMC) for specifically listed industrial fan models.

productcate-527-746
productcate-527-746
productcate-527-746

 

FAQ

 

Q: Which centrifugal fan series should I choose for general ventilation?

A: For general ventilation and clean-air applications, standard ventilation series such as 4-72 or 4-68 may be suitable, depending on the required airflow, pressure, temperature, and installation conditions. Review the series performance data to identify the appropriate model for your operating point.

Q: Which centrifugal fan is suitable for higher system resistance?

A: A higher-pressure centrifugal fan series such as 4-79, 9-19, or 9-26 may be considered when the system has greater resistance from long duct runs, filters, cyclones, dampers, or other process equipment. The required airflow and pressure should be confirmed before selecting the fan series.

Q: When should I choose a high-pressure centrifugal fan?

A: A high-pressure centrifugal fan is typically considered when the required system pressure cannot be met by a standard ventilation fan. Applications may include forced air supply, pneumatic conveying, burner air supply, and other systems with high resistance. Selection should be based on the required airflow and pressure at the operating point.

Q: Which centrifugal fan is suitable for dusty or particulate-laden air?

A: For dusty air, the impeller design, material, particle concentration, particle size, and required pressure should be considered together. Radial-blade configurations may be suitable for certain dust-handling duties because their blade geometry is less prone to material accumulation. The actual medium should be provided for fan selection.

Q: Should I choose direct drive or belt drive for a centrifugal fan?

A: Direct drive provides a compact arrangement with fewer transmission components, while belt drive allows fan speed adjustment through pulley selection and can help separate the motor from hot or humid operating conditions. The appropriate drive depends on fan speed, motor power, temperature, duty cycle, and installation requirements.

Q: Can you recommend a centrifugal fan based on my operating conditions?

A: Yes. Provide the required airflow, static or total pressure, gas temperature, medium, dust or corrosion conditions, installation requirements, motor power supply, and quantity. For replacement projects, an existing fan model, nameplate, drawing, performance curve, or photos can also be provided.

Q: Can you replace an existing or obsolete centrifugal fan?

A: Yes. Existing fan dimensions, nameplate data, airflow and pressure requirements, motor information, mounting dimensions, and photos can be used to evaluate a replacement configuration. Where applicable, the replacement fan can be matched to the existing installation and required operating point.

We're known as one of the most reliable centrifugal fans manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy advanced centrifugal fans made in China here from our factory. All customized products are with high quality and competitive price.

Send Inquiry

Send Inquiry