Roof Exhaust Fans

Roof Exhaust Fans

 

Roof exhaust fans remove heat, smoke, moisture, dust, and various process exhaust gases from industrial and commercial buildings. QIYUE FAN offers a wide range of roof-mounted axial and centrifugal exhaust fan configurations to meet diverse requirements regarding airflow, static pressure, roof clearance, and installation.


The product lineup includes direct-drive, low-profile, high-capacity, and axial roof exhaust fan designs, with configurations available to support continuous operation and project-specific roof integration.

 

 
  • Direct Drive Roof Exhaust Fan
    The Direct Drive Roof Exhaust Fan is a roof-mounted ventilation fan for continuous exhaust in commercial and industrial buildings. The direct-drive motor connects directly to the fan wheel,...
    read more
  • Low Profile Roof Exhaust Fan
    The Low Profile Roof Exhaust Fan is a roof-mounted centrifugal exhaust fan designed for buildings with limited roof clearance, architectural height restrictions or a need to reduce equipment...
    read more
  • High Volume Roof Exhaust Fan
    The High Volume Roof Exhaust Fan is a roof-mounted ventilation fan designed for large-span buildings requiring high-capacity air exhaust. It is available in centrifugal and propeller...
    read more
  • Axial Roof Exhaust Fan
    The Axial Roof Exhaust Fan is a roof-mounted axial exhaust fan designed for high-volume air extraction in industrial, commercial and agricultural buildings. It is used for continuous removal of...
    read more
 

Roof Exhaust Fan Series

 
 
01
 

Direct Drive Roof Exhaust Fans

Featuring a direct-drive motor configuration, these fans are ideal for roof exhaust systems requiring a compact drive layout and minimal belt maintenance. They are available in both upblast and downblast configurations.

 
02
 

Low Profile Roof Exhaust Fans

Designed for projects with limited roof clearance or building height restrictions, these fans feature a low-profile design. They are available in direct-drive or belt-drive configurations and cover a wide range of airflow capacities.

 
03
 

High Volume Roof Exhaust Fan

Suitable for large-span buildings requiring high-volume exhaust. This series handles higher airflow ranges and can be configured with direct-drive or belt-drive systems based on specific project conditions.

 
04
 

Axial Roof Exhaust Fans

Utilizing an axial flow design, these fans are suitable for roof exhaust applications requiring high airflow and low static pressure. They are available in both direct-drive and belt-drive options.

Direct Drive Roof Exhaust Fan

 

Roof Exhaust Fan Selection by Project Requirement

 

Project Requirement

Key Selection Factor

Fan Type / Configuration

General roof exhaust

Airflow + static pressure + discharge arrangement

Select fan type and drive according to duty

Limited roof height

Fan height + clearance + airflow

Low Profile Roof Exhaust Fan

Large building air extraction

Required airflow + system volume

High Volume Roof Exhaust Fan

High airflow / lower pressure

Airflow + static pressure

Axial Roof Exhaust Fan

Compact drive arrangement

Fan duty + maintenance space

Direct Drive Roof Exhaust Fan

 

Upblast and Downblast Exhaust
 

Roof discharge direction affects how exhaust leaves the building and how the fan interfaces with the roof.

Discharge

Typical Selection

Upblast

Directs exhaust upward and away from the roof surface; suitable where vertical discharge is required.

Downblast

Directs exhaust downward toward the roof area; suitable for applications where this discharge arrangement is acceptable

 

Drive Configuration

 

Drive Type

Selection Difference

Typical Use

Direct Drive

Motor connects directly to the fan assembly; compact arrangement with no belts or pulleys.

Restricted maintenance space, compact roof installations, fixed-speed operation

Belt Drive

Fan speed can be adjusted through the drive arrangement; motor is separated from the fan shaft.

Larger units and applications requiring fan-speed adjustment

 

Roof Installation & Building Integration
 

Qiyue Fan configures roof exhaust units to align with existing roof curbs, structural penetrations, duct risers, and clearance constraints before manufacturing.

Integration Item

Engineering Adaptation

Roof Curb Fitting

Base and cap interfaces are custom-sized for concrete, self-flashing, or insulated steel curbs with drip edges.

Opening & Duct Alignment

Inlet dimensions and companion flanges connect directly to roof openings and vertical duct risers without adapters.

Discharge Direction

Upblast (vertical discharge away from roof)

Downblast (downward discharge for ambient exhaust).

Profile & Clearance

Low-profile housing options available for height-restricted roofs; load distributed across curb frames.

Outdoor Protection

Continuously welded casings with rain cowls, gravity backdraft dampers, and IP65/NEMA outdoor motor covers.

Vibration Isolation

Base structures fitted with internal neoprene or spring isolators to prevent structural resonance.

Maintenance Access

Access panels and external lubrication points positioned within roof clearance for routine servicing.

 

Roof Exhaust Fan Configurations
 

QIYUE FAN provides project-specific configuration for the following items:

Customizable Item

Available Specifications

Fan Type

Axial/centrifugal

Drive

Direct drive/belt drive

Motor

Power, voltage, frequency, phase, VFD

Fan Speed

RPM

Discharge

Upblast / downblast, discharge position

Fan Size

Diameter, height, overall dimensions

Material

Carbon steel, galvanized steel, aluminum, stainless steel

Roof Interface

Curb size, base, inlet/outlet, mounting holes

Mounting

Roof curb / structural support

Protection

Weather hood, bird screen, backdraft damper

 

How We Ensure Our Product Quality
 

Structural & Weatherproof Fabrication
Roof hoods, mounting curbs, and housings are fabricated from heavy-gauge galvanized steel or aluminum using continuous welding processes.

 

Duct & Curb Interface Precision
Roof mounting curbs and transition flanges are cut and formed to project-specific dimensions, ensuring precise alignment with existing roof openings and ductwork systems.

 

Two-Plane Dynamic Balancing
Impellers undergo dynamic balancing on horizontal balancing machines (compliant with ISO 1940 / AMCA 204 standards) to minimize operational vibration, reduce noise, and preserve bearing integrity.

 

Outdoor Drive & Component Alignment
Motors, shafts, and drive components are precision-aligned using laser alignment tools and dial indicators to prevent belt wear, shaft fatigue, and efficiency losses under continuous load.

 

Pre-Shipment Factory Acceptance Testing (FAT)
Complete units undergo operational inspections before shipment, with key parameters verified using optical tachometers, dry film thickness (DFT) gauges, and vibration meters.

 

Compliance & Audited Quality Systems
 

Integrated Management Systems: Manufacturing operations adhere to ISO 9001, ISO 14001, and ISO 45001.


Third-Party Verification: Facilities and business operations are audited on-site by TÜV Rheinland, with applicable industrial series covered by EAEU Declarations of Conformity for regional market entry.


Traceable Documentation: Project-specific Material Test Reports (MTR), dynamic balancing certificates, and factory test logs are archived and provided before shipment.

productcate-527-746
productcate-527-746
productcate-527-746

 

FAQ

 

Q: How do I select a roof exhaust fan?

A: Start with the required airflow and static pressure, then confirm the roof opening, installation height, discharge arrangement, motor requirements, and exhaust conditions.

Q: When should I choose a low-profile roof exhaust fan?

A: A low-profile configuration is appropriate when roof height, clearance, or overall fan height is restricted. QIYUE's listed low-profile series is specifically designed around reduced installation height.

Q: What is the difference between axial and centrifugal roof exhaust fans?

A: Axial roof exhaust fans are typically used for high airflow with lower system resistance. Centrifugal configurations are considered where greater pressure capability or a specific exhaust construction is required.

Q: When is direct drive preferable to belt drive?

A: Direct drive provides a more compact transmission arrangement and eliminates belts and pulleys. Belt drive provides greater flexibility for fan-speed adjustment and motor positioning.

Q: Can roof exhaust fans be integrated with existing ductwork?

A: Yes. Fan inlet/outlet dimensions, roof interface, mounting arrangement, and motor position can be coordinated with the existing duct and building layout.

Q: Can QIYUE FAN supply roof exhaust fans for EPC and OEM projects?

A: Yes. Fan performance, dimensions, mounting, electrical configuration, duct connections, and project-specific requirements can be coordinated for EPC and OEM applications.

We're known as one of the most reliable roof exhaust fans manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy advanced roof exhaust fans made in China here from our factory. All customized products are with high quality and competitive price.

Send Inquiry

Send Inquiry