Roof Exhaust Fans
Roof Exhaust Fans
Roof exhaust fans remove heat, smoke, moisture, dust, and various process exhaust gases from industrial and commercial buildings. QIYUE FAN offers a wide range of roof-mounted axial and centrifugal exhaust fan configurations to meet diverse requirements regarding airflow, static pressure, roof clearance, and installation.
The product lineup includes direct-drive, low-profile, high-capacity, and axial roof exhaust fan designs, with configurations available to support continuous operation and project-specific roof integration.
-
Direct Drive Roof Exhaust FanThe Direct Drive Roof Exhaust Fan is a roof-mounted ventilation fan for continuous exhaust in commercial and industrial buildings. The direct-drive motor connects directly to the fan wheel,...read more
-
Low Profile Roof Exhaust FanThe Low Profile Roof Exhaust Fan is a roof-mounted centrifugal exhaust fan designed for buildings with limited roof clearance, architectural height restrictions or a need to reduce equipment...read more
-
High Volume Roof Exhaust FanThe High Volume Roof Exhaust Fan is a roof-mounted ventilation fan designed for large-span buildings requiring high-capacity air exhaust. It is available in centrifugal and propeller...read more
-
Axial Roof Exhaust FanThe Axial Roof Exhaust Fan is a roof-mounted axial exhaust fan designed for high-volume air extraction in industrial, commercial and agricultural buildings. It is used for continuous removal of...read more
Roof Exhaust Fan Series
Direct Drive Roof Exhaust Fans
Featuring a direct-drive motor configuration, these fans are ideal for roof exhaust systems requiring a compact drive layout and minimal belt maintenance. They are available in both upblast and downblast configurations.
Low Profile Roof Exhaust Fans
Designed for projects with limited roof clearance or building height restrictions, these fans feature a low-profile design. They are available in direct-drive or belt-drive configurations and cover a wide range of airflow capacities.
High Volume Roof Exhaust Fan
Suitable for large-span buildings requiring high-volume exhaust. This series handles higher airflow ranges and can be configured with direct-drive or belt-drive systems based on specific project conditions.
Axial Roof Exhaust Fans
Utilizing an axial flow design, these fans are suitable for roof exhaust applications requiring high airflow and low static pressure. They are available in both direct-drive and belt-drive options.

Roof Exhaust Fan Selection by Project Requirement
|
Project Requirement |
Key Selection Factor |
Fan Type / Configuration |
|
General roof exhaust |
Airflow + static pressure + discharge arrangement |
Select fan type and drive according to duty |
|
Limited roof height |
Fan height + clearance + airflow |
Low Profile Roof Exhaust Fan |
|
Large building air extraction |
Required airflow + system volume |
High Volume Roof Exhaust Fan |
|
High airflow / lower pressure |
Airflow + static pressure |
Axial Roof Exhaust Fan |
|
Compact drive arrangement |
Fan duty + maintenance space |
Direct Drive Roof Exhaust Fan |
Upblast and Downblast Exhaust
Roof discharge direction affects how exhaust leaves the building and how the fan interfaces with the roof.
|
Discharge |
Typical Selection |
|
Upblast |
Directs exhaust upward and away from the roof surface; suitable where vertical discharge is required. |
|
Downblast |
Directs exhaust downward toward the roof area; suitable for applications where this discharge arrangement is acceptable |
Drive Configuration
|
Drive Type |
Selection Difference |
Typical Use |
|
Direct Drive |
Motor connects directly to the fan assembly; compact arrangement with no belts or pulleys. |
Restricted maintenance space, compact roof installations, fixed-speed operation |
|
Belt Drive |
Fan speed can be adjusted through the drive arrangement; motor is separated from the fan shaft. |
Larger units and applications requiring fan-speed adjustment |
Roof Installation & Building Integration
Qiyue Fan configures roof exhaust units to align with existing roof curbs, structural penetrations, duct risers, and clearance constraints before manufacturing.
|
Integration Item |
Engineering Adaptation |
|
Roof Curb Fitting |
Base and cap interfaces are custom-sized for concrete, self-flashing, or insulated steel curbs with drip edges. |
|
Opening & Duct Alignment |
Inlet dimensions and companion flanges connect directly to roof openings and vertical duct risers without adapters. |
|
Discharge Direction |
Upblast (vertical discharge away from roof) Downblast (downward discharge for ambient exhaust). |
|
Profile & Clearance |
Low-profile housing options available for height-restricted roofs; load distributed across curb frames. |
|
Outdoor Protection |
Continuously welded casings with rain cowls, gravity backdraft dampers, and IP65/NEMA outdoor motor covers. |
|
Vibration Isolation |
Base structures fitted with internal neoprene or spring isolators to prevent structural resonance. |
|
Maintenance Access |
Access panels and external lubrication points positioned within roof clearance for routine servicing. |
Roof Exhaust Fan Configurations
QIYUE FAN provides project-specific configuration for the following items:
|
Customizable Item |
Available Specifications |
|
Fan Type |
Axial/centrifugal |
|
Drive |
Direct drive/belt drive |
|
Motor |
Power, voltage, frequency, phase, VFD |
|
Fan Speed |
RPM |
|
Discharge |
Upblast / downblast, discharge position |
|
Fan Size |
Diameter, height, overall dimensions |
|
Material |
Carbon steel, galvanized steel, aluminum, stainless steel |
|
Roof Interface |
Curb size, base, inlet/outlet, mounting holes |
|
Mounting |
Roof curb / structural support |
|
Protection |
Weather hood, bird screen, backdraft damper |
How We Ensure Our Product Quality
Structural & Weatherproof Fabrication
Roof hoods, mounting curbs, and housings are fabricated from heavy-gauge galvanized steel or aluminum using continuous welding processes.
Duct & Curb Interface Precision
Roof mounting curbs and transition flanges are cut and formed to project-specific dimensions, ensuring precise alignment with existing roof openings and ductwork systems.
Two-Plane Dynamic Balancing
Impellers undergo dynamic balancing on horizontal balancing machines (compliant with ISO 1940 / AMCA 204 standards) to minimize operational vibration, reduce noise, and preserve bearing integrity.
Outdoor Drive & Component Alignment
Motors, shafts, and drive components are precision-aligned using laser alignment tools and dial indicators to prevent belt wear, shaft fatigue, and efficiency losses under continuous load.
Pre-Shipment Factory Acceptance Testing (FAT)
Complete units undergo operational inspections before shipment, with key parameters verified using optical tachometers, dry film thickness (DFT) gauges, and vibration meters.
Compliance & Audited Quality Systems
Integrated Management Systems: Manufacturing operations adhere to ISO 9001, ISO 14001, and ISO 45001.
Third-Party Verification: Facilities and business operations are audited on-site by TÜV Rheinland, with applicable industrial series covered by EAEU Declarations of Conformity for regional market entry.
Traceable Documentation: Project-specific Material Test Reports (MTR), dynamic balancing certificates, and factory test logs are archived and provided before shipment.



FAQ
We're known as one of the most reliable roof exhaust fans manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy advanced roof exhaust fans made in China here from our factory. All customized products are with high quality and competitive price.