Mixed Flow Fans

Mixed flow fans combine axial airflow characteristics with centrifugal pressure capabilities. They maintain a compact, in-line duct layout while meeting pressure requirements that exceed those of traditional axial fans. QIYUE FAN offers a range of mixed-flow fans suitable for industrial ventilation, exhaust, and ducting systems.

 

 
  • Mixed Flow Exhaust Fan
    Mixed-flow exhaust fans combine axial airflow with centrifugal pressure generation, providing balanced airflow and pressure for commercial and industrial ventilation. They support in-line duct...
    read more
  • Mixed Flow Ventilation Fan
    The mixed-flow ventilation fan is an inline duct fan for supply and exhaust applications in commercial and industrial HVAC systems. It combines axial airflow with centrifugal pressure generation,...
    read more
  • Heavy Duty Mixed Flow Fan
    The Heavy Duty Mixed Flow Fan bridges the performance gap between traditional axial and centrifugal fans. By channeling air through a diagonal impeller path, this unit generates higher static...
    read more
  • Industrial Mixed Flow Fan
    Industrial Mixed Flow Fans combine axial airflow capacity with higher static-pressure capability for inline industrial ventilation. The mixed-flow impeller provides straight-through airflow with...
    read more
  • High Pressure Mixed Flow Fan
    The High Pressure Mixed Flow Fan is an industrial inline ventilation unit engineered to combine the high volumetric airflow rates of axial fans with the pressure-generating characteristics of...
    read more
 
Mixed Flow Ventilation Fan

 

Mixed Flow Fan Series

Mixed Flow Exhaust Fans
For industrial exhaust and duct extraction where airflow must be maintained against higher system resistance than conventional axial fans.

Mixed Flow Ventilation Fans
An in-line configuration for general ventilation, air exchange, and ducted airflow with moderate pressure requirements.

Heavy Duty Mixed Flow Fans
Built for continuous industrial service with heavier construction for demanding ventilation and exhaust conditions.

Industrial Mixed Flow Fans
Compact mixed-flow construction for industrial air-handling systems requiring a balance between airflow capacity and pressure performance.

High Pressure Mixed Flow Fans
Developed for duct systems where filters, fittings, long duct runs, or other components create higher pressure losses.

 

Axial vs Mixed Flow vs Centrifugal
 

The three fan types serve different combinations of airflow, pressure, and installation requirements.

Selection Factor

Axial Flow Fan

Mixed Flow Fan

Centrifugal Fan

Airflow

High

Moderate to high

Low to high, depending on design

Pressure Capability

Low to moderate

Moderate to high

Moderate to high

Airflow Path

Straight-through

Straight-through

Typically changes direction through the housing

Installation

Compact inline

Compact inline

Larger or more layout-dependent

System Resistance

Lower-resistance systems

Moderate-resistance duct systems

Higher-resistance systems

Space Constraint

Good

Very good

More installation space may be required

Typical Selection

Large airflow with lower pressure

Higher pressure with inline installation

Higher pressure or more complex system resistance

Typical Application

General ventilation, air exchange

Ducted ventilation, exhaust and air handling

Process exhaust, dust collection and high-pressure systems

 

Mixed Flow Fan Selection by Operating Duty
 

Mixed-flow fans are typically considered when axial-flow fans cannot provide sufficient pressure, yet traditional centrifugal fans would result in overly complex installation or occupy excessive space.

Operating Requirement

Key Selection Factor

Suitable Fan Type

General inline ventilation

Airflow + static pressure

Mixed Flow Ventilation Fan

Industrial exhaust

Airflow + system pressure

Mixed Flow Exhaust Fan

Continuous/demanding duty

Airflow + pressure + operating duty

Heavy Duty Mixed Flow Fan

General industrial air handling

Airflow + pressure + installation

Industrial Mixed Flow Fan

Higher system resistance

Airflow + total system pressure loss

High Pressure Mixed Flow Fan

 

Inline Installation & System Integration
 

QIYUE FAN mixed flow fans can be configured for different duct layouts, installation spaces, airflow requirements, and equipment interfaces. The main configuration differences are shown below.

Configuration

Key Difference

Suitable For

Standard Inline

Straight-through inlet and outlet on the same axis

Conventional ducted ventilation and exhaust

Compact Inline

Smaller overall footprint for restricted installation space

Equipment rooms, packaged units and space-limited layouts

Horizontal Mounting

Fan installed horizontally with the support arrangement matched to the equipment or structure.

Floor-mounted and horizontal duct systems

Vertical Mounting

Fan arranged vertically with suitable support and motor positioning

Vertical shafts, risers and space-constrained installations

Direct Drive

Motor directly drives the impeller with a compact transmission arrangement.

Compact systems and fixed-speed applications

For EPC and OEM projects, the selected configuration can be coordinated with the airflow, static pressure, duct layout, installation space, operating medium, and equipment interface.

 

Custom Mixed Flow Fan Configurations

 

Configuration

Typical Options

Drive

Direct drive/belt drive

Motor & Control

Fixed speed / VFD

Impeller

Mixed-flow impeller selected for duty

Material

Carbon steel / stainless steel / special materials where required

Temperature

Standard or temperature-suitable construction

Installation

Horizontal/vertical / equipment-integrated

Connections

Duct-matched inlet/outlet arrangement

 

 
Quality Assurance
 
01/

Raw Material Verification
Upon arrival, steel plates are verified for thickness and material grade using digital calipers and ultrasonic thickness gauges to ensure casing rigidity and structural integrity.

02/

Welding Quality and Structural Inspection
Impeller blades and casings are welded by certified welders; critical load-bearing welds are validated via Ultrasonic Testing (UT) or Magnetic Particle Testing (MT).

03/

Precision Dynamic Balancing
Each impeller undergoes balancing on a horizontal dynamic balancing machine (compliant with AMCA 204 / ISO 1940 standards) to eliminate rotational imbalance, reduce operating noise, and prevent premature bearing wear.

04/

Laser Alignment and Dial Indicator Calibration
Laser alignment tools and dial indicators are used to align the motor, shaft, bearings, and coupling, preventing angular misalignment, thermal expansion damage, and efficiency losses.

05/

Pre-shipment Factory Acceptance Testing (FAT)
Following complete assembly, the unit undergoes operational testing prior to shipment, including rotational speed verification, coating quality inspection, and vibration testing.

06/

Traceable Quality Documentation
Comprehensive Quality Control (QC) records—including Material Test Reports (MTRs), dynamic balancing certificates, and factory test records—are compiled and provided to ensure full project traceability.

 

Qualification & Compliance
 

Shandong Qiyue Fan Co., Ltd. maintains ISO 9001, ISO 14001, and ISO 45001 certified management systems.


Relevant industrial fan models are covered by an EAEU Declaration of Conformity where applicable, and QIYUE FAN has completed a TÜV Rheinland supplier audit covering site existence and business operations.


Product-specific certification and compliance requirements are confirmed according to the selected model and destination market.

productcate-527-746
productcate-527-746
productcate-527-746

FAQ

 

Q: When should I choose a mixed flow fan instead of an axial fan?

A: Consider a mixed flow fan when the system requires higher pressure than a conventional axial fan while a compact inline installation is still preferred.

Q: How should a mixed flow fan be selected?

A: Select the fan based on the required airflow and static pressure at the operating point, then confirm duct dimensions, system resistance, installation conditions, and motor requirements.

Q: What causes the required pressure in a mixed flow system?

A: Ductwork, elbows, filters, dampers, silencers, and other system components contribute to total system resistance and should be included in the pressure requirement.

Q: Can mixed flow fans be used for OEM equipment?

A: Yes. Fan dimensions, mounting, motor configuration, connections, and other equipment interfaces can be coordinated for OEM applications.

Q: Can mixed flow fans be configured for dusty or corrosive air?

A: Yes, where supported by the selected model. Impeller construction and materials should be matched to the actual dust loading, corrosive medium, temperature, and operating conditions.

We're known as one of the most reliable mixed flow fans manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy advanced mixed flow fans made in China here from our factory. All customized products are with high quality and competitive price.

Send Inquiry

Send Inquiry