Key Specifications

 

Parameter

Specification

Airflow

1,200–12,000 CFM

Static Pressure

500–2,500 Pa

Motor Power

1.5–18.5 kW / 2–25 HP

Power Supply

220–480 V, 3 Phase, 50/60 Hz

Impeller

Backward-curved centrifugal

Operating Temperature

-20°C to +80°C

Motor Protection

IP55

Housing

3–5 mm Carbon Steel / Stainless Steel

Noise Level

68–82 dB(A) at 1.5 m

Drive

Direct Drive / V-Belt Drive

 

Fan Construction

 

Impeller: Backward-curved centrifugal impeller, dynamically balanced before assembly to control rotational imbalance.


Housing: 3–5 mm carbon steel or stainless steel housing for the specified exhaust duty.


Motor: IP55 motor matched to the ordered power supply and fan capacity.


Drive: Direct-drive or V-belt drive arrangement according to the selected fan configuration.

 

Performance

 

Stable Airflow Under Resistance: Backward-curved blades maintain consistent airflow as duct and filter resistance increases, supporting effective fume extraction.


Low Rotational Vibration: Dynamic impeller balancing reduces rotational imbalance, helping maintain smoother fan operation.


Stable Motor Operation: IP55 motor protection helps protect the motor against dust and water ingress under the specified operating conditions.

 

System Matching

 

The fan operates as the air-moving unit in a welding fume extraction system:


Capture Hood / Extraction Arm → Ductwork → Filter → Exhaust Fan → Discharge


Select the fan according to the required airflow at total system static pressure, not airflow alone. The pressure calculation should include extraction arms, duct length, elbows, dampers, filters or dust collectors, and discharge resistance.

 

Applications

 

Welding Booths: Connects with extraction arms or hoods for individual welding stations.


Robotic Welding Cells: Used with fixed extraction hoods or centralized duct systems.


Metal Fabrication Plants: Suitable for centralized extraction serving multiple welding stations.


Heavy Steel Fabrication: Used where larger duct systems require higher airflow and static pressure.


Centralized Fume Extraction Systems: Installed downstream of the filtration unit as the system exhaust fan.

 

Customization

 

Customization Item

Parameters to Confirm

Air Performance

Required airflow, static pressure and fan speed

Motor

Motor power, voltage, frequency and phase

Housing Material

Carbon steel or stainless steel

Impeller

Impeller size, blade configuration and material

Drive

Direct drive or V-belt drive

Air Connections

Inlet diameter, outlet diameter, flange dimensions and orientation

Installation

Mounting dimensions and base arrangement

 

Project Documentation

GA Drawing

Overall dimensions, mounting points and inlet/outlet locations.

Fan Performance Curve

Airflow and static-pressure reference for system matching.

Motor Datasheet

Motor power supply and operating data.

Installation & O&M Instructions

Installation, operation and routine maintenance reference.

Test Records

Factory inspection and running-test records where applicable.

Certificates

Applicable certificates for the ordered configuration.

Spare Parts Information

Model-matched replacement parts for future maintenance.

 

Maintenance

 

Impeller: Remove accumulated fume and dust; check blades for damage or imbalance.


Bearings: Check operating temperature, abnormal noise and lubrication condition.


Motor: Inspect terminals, cooling passages and operating temperature.


Belt Drive: Check belt tension, belt wear and pulley alignment on belt-driven models.


Housing & Duct Connections: Check fasteners, air leakage and visible corrosion.


Filter: Monitor filter loading and pressure drop to avoid excessive system resistance.


Vibration: Check for abnormal vibration after cleaning, maintenance or component replacement.

 

RFQ Information

 

01/

Required Airflow: CFM or m³/h

02/

Required Static Pressure: Pa or in. wg

03/

Extraction Points: Total number of welding stations or extraction arms

04/

Simultaneous Operation: Number of extraction points operating at the same time

05/

Duct System: Duct diameter, approximate length, elbows and major fittings

06/

Filter / Dust Collector: Model or pressure loss, if applicable

07/

Process Conditions: Welding process, workpiece material and extracted air temperature

08/

Power Supply: Voltage, phase and frequency

09/

Installation: Indoor or outdoor location, mounting arrangement and available space

10/

Quantity: Required fan quantity

 

FAQ

 

Q: What is the difference between a welding fume exhaust fan and a general ventilation fan?

A: A welding fume exhaust fan is selected for ducted extraction systems that require defined airflow and static pressure, rather than general air circulation.

Q: Can one welding fume exhaust fan serve multiple welding stations?

A: Yes. A centralized fan can serve multiple extraction points through a connected duct system when the system is designed for the required operating points.

Q: Can this fan be used with a dust collector or fume filter?

A: Yes. The fan can be installed as part of a filtered extraction system, with the filter or dust collector positioned upstream of the exhaust fan.

Q: Can the fan be used for welding fumes containing metal particles?

A: Yes. The fan is designed for welding fume extraction involving airborne metal particulates generated during welding and fabrication processes.

Q: Can this welding fume exhaust fan replace an existing industrial exhaust fan?

A: Yes. Replacement selection can be based on the existing fan's performance, motor data, connection dimensions and mounting dimensions.

Q: What information is needed to select a replacement welding fume fan?

A: The existing fan model or nameplate data, airflow and static pressure requirements, inlet/outlet dimensions, mounting dimensions and available installation space are required.

Q: Is a centrifugal fan suitable for long duct runs?

A: Yes. The backward-curved centrifugal design is intended for ducted exhaust systems where airflow must overcome system resistance.

Hot Tags: welding fume exhaust fan, China welding fume exhaust fan manufacturers, suppliers, factory, fume smoke exhaust fans, Heavy Duty Smoke Exhaust Fan, High Temperature Smoke Exhaust Fan, Industrial Fume Exhaust Fan, Industrial Smoke Exhaust Fan, Welding Fume Exhaust Fan

Send Inquiry

Send Inquiry