The High Pressure Mixed Flow Fan is an industrial inline ventilation unit engineered to combine the high volumetric airflow rates of axial fans with the pressure-generating characteristics of centrifugal blowers. This equipment overcomes system resistance in long duct runs, tight bends, and inline filtration setups.
Technical Specifications
|
Parameter |
Specification Range |
Standard / Test Condition |
|
Airflow Capacity |
800 to 15,000 m3/h (470 to 8,830 CFM) |
Free air to maximum static pressure |
|
Static Pressure |
Up to 1,200 Pa (4.8 in. wg) |
ISO 5801 chamber test |
|
Impeller Diameter |
315 mm to 800 mm |
Nominal size matrix |
|
Motor Input Power |
0.37 kW to 18.5 kW |
3-phase, 380V/415V/480V, 50Hz/60Hz |
|
Motor Efficiency |
IE3 / IE4 energy efficiency classes |
IEC 60034-30-1 |
|
Operating Temperature |
-20°C to +60°C (Standard) / Up to +150°C (High-Temp) |
Continuous duty |
|
Ingress Protection |
IP54 / IP55 terminal box and motor enclosure |
IEC 60529 |
|
Acoustic Output |
58 dBA to 78 dBA @ 3 meters |
Free-field sound pressure |
Ventilation System Applications
Underground Infrastructure: Including multi-level parking garages, utility vaults, and service tunnels.
Extended Ductwork Integration: Industrial exhaust and supply air routing through high-resistance, extended duct networks.
HVAC Inline Boosting: Commercial HVAC inline airflow boosting across high static pressure duct circuits.
Industrial Process Air Exchange: Process air circulation and heat removal in non-explosive, non-corrosive industrial environments.
Operating Limitation: Standard models are designed for clean or light-duty air; they are not rated for explosive gases, aggressive chemical mists, or heavy dust loads.
Impeller Geometry & Pressure Generation
Airflow & Pressure Integration: Mixed-flow impeller design integrates axial flow volume with radial pressure boost, delivering higher static pressure than standard axial fans.
Factory-Set Pitch Angles: Factory-set blade pitch angles are precision-fixed during manufacturing to optimize specific operating duty points and eliminate field-adjustment errors.
Dynamic Balance Verification: Fully assembled impellers undergo dynamic balancing before casing integration to prevent vibration, wear, and mechanical strain.
Motor Power & Speed Options
Broad Operating Speed Range: Standard motor operating speeds range from 960 to 2,900 RPM across 2-pole, 4-pole, and 6-pole configurations based on line frequency.
VFD Speed Control Compatibility: Direct-drive designs integrate smoothly with Variable Frequency Drives (VFDs) for precise system speed regulation and air balancing.
Mechanical Structure & Maintenance
Heavy-Duty Casing Design: The continuously welded, heavy-gauge carbon steel casing maintains structural rigidity and tight tip clearances under continuous high-pressure loads.
Direct-Drive Maintenance Efficiency: The direct-drive motor eliminates belts and pulleys, reducing alignment requirements and routine maintenance downtime.
Precision Component Engineering: Precision-machined carbon steel drive shafts and heavy-duty bearings are selected for the required shaft load, rotational speed, and continuous operation.
Convenient Inspection Access: An integrated inspection hatch provides quick access to the impeller.
Manufacturing Capacity
Verified Production Facility: Manufactured by Shandong Qiyue Fan Co., Ltd. in a 10,500 ㎡ production facility located in Zibo, Shandong, China.
In-House Manufacturing Control: Complete in-house production control spanning steel cutting, plate forming, impeller welding, dynamic balancing, and final run testing.
Certified Quality Management: Operations certified under ISO 9001 (Quality), ISO 14001 (Environment), and ISO 45001 (Occupational Health & Safety) management standards.
End-to-End Project Engineering: Full technical project support available, including CAD drawing approval, custom structural tailoring, standardized production scheduling, and export packaging.
FAQ
Q: What is the MOQ, and can you accept a single-unit trial order?
A: A single trial unit can usually be provided for evaluation at a higher unit price. Bulk MOQ and pricing depend on impeller size and motor configuration.
Q: What is the lead time for standard and customized models?
A: Standard models typically ship within 20–30 days. Custom units with high-temperature windings, non-standard voltage, or integrated VFD panels require approximately 35–45 days, depending on order volume.
Q: Can you provide a performance curve for our duty point?
A: Yes. We can provide ISO 5801-compliant airflow and static-pressure curves, along with the corresponding test report, for the selected model.
Q: Do you offer factory acceptance or witnessed testing?
A: Yes. We can conduct FAT at our facility, with video/photo documentation or a third-party inspection agency, before packing and shipment.
Q: What warranty applies?
A: The motor and mechanical assembly are covered against manufacturing defects. Transit damage is handled through freight insurance, so coverage should be confirmed before shipment.
Q: Can the casing and flange dimensions match existing ductwork?
A: Yes. Flange dimensions, casing orientation, and inlet/outlet configurations can be customized without a complete engineering redesign.
Q: Are installation drawings, wiring diagrams, and commissioning support provided?
A: Yes. We provide installation drawings, wiring diagrams, commissioning checklists, and remote technical support during installation and startup.
Q: What is the availability and lead time for spare parts?
A: Common parts, including bearings and motors, are generally stocked or available on short lead times. A spare-parts agreement is recommended for priority future supply.
Hot Tags: high pressure mixed flow fan, China high pressure mixed flow fan manufacturers, suppliers, factory, Heavy Duty Mixed Flow Fan, High Pressure Mixed Flow Fan, Industrial Mixed Flow Fan, Mixed Flow Exhaust Fan, mixed flow fans, Mixed Flow Ventilation Fan