QIYUE manufactures industrial centrifugal fans for boiler forced draft, induced draft, furnace exhaust, kiln exhaust, and high-temperature thermal process applications. The range includes standard boiler fan series and high-temperature configurations with shaft heat dissipation, bearing protection, and temperature-oriented mechanical construction.


Fan selection is based on the required airflow, total pressure, continuous temperature, peak temperature, operating cycle, drive arrangement, and installation dimensions.

 

 
  • Boiler Forced Draft Fans
    The Boiler Forced Draft (FD) Fan supplies ambient or preheated combustion air to industrial boilers, furnaces, and burner systems under positive pressure. Fan selection is based on required...
    read more
  • Boiler Induced Draft Fans
    Boiler induced draft (ID) fans extract flue gas from industrial boiler systems, maintain the required furnace negative pressure, and overcome resistance from boiler passes, heat exchangers, dust...
    read more
 
Boiler & High-Temperature Fan Product Range
 

Small & Medium Boiler ID Fans
Y6-30 Series: Compact centrifugal draft fan for small-to-medium industrial boilers requiring reliable negative pressure flue-gas extraction.

 

Standard & Dust-Collection ID Fans
Y5-47 Series: Standard boiler flue-gas exhaust configuration for installation downstream of heat exchangers, economizers, and primary filters.
Y5-48 Series: High-static-head fan designed for flue routes with elevated system resistance from dust collectors, scrubbers, and exhaust stacks.

 

Large-Capacity & Fluidized-Bed Draft Systems

GY6-51 Series: High-volume centrifugal fan engineered for utility boilers and circulating fluidized-bed (CFB) draft circuits requiring continuous operation.

Y8-39 / Y9-38 Series: Heavy-duty exhaust fans built to overcome significant pressure drops across extended duct networks and multi-stage filtration units.

 

Dual-Duty & Heavy Industrial Draft Fans
G/Y4-73 Series: Heavy-duty series configured as G4-73 for fresh air supply (FD) or Y4-73 for flue-gas extraction (ID) based on system duty reviews.
GY5-51 Series: Flexible draft fan for boiler routes where site operating conditions confirm airflow orientation (forced or induced draft).
GY6-41 Series: Industrial centrifugal blower delivering stable volumetric airflow and pressure reserves for primary boiler draft systems.

 

Large-Capacity & Fluidized-Bed Draft Systems
GY6-51 Series: High-volume centrifugal fan engineered for utility boilers and circulating fluidized-bed (CFB) draft circuits requiring continuous operation.

 

Technical Selection Matrix

 

Fan Series

Max Operating Temp.

Pressure Profile

Application Duty

Drive & Shaft Features

Y6-30 / Y5-47 / Y5-48

250°C

Low to Medium-High

Small/medium boiler ID & filtration exhaust

Compact casing, heat-dissipation disc options

G/Y4-73 & GY5-51

250°C

Medium Head

Forced draft combustion or induced flue duty

Dual-duty centrifugal impeller, direct/coupling drive

GY6-41 / Y8-39 / Y9-38

400°C

High Pressure

High-resistance boiler exhaust & industrial blowers

Reinforced alloy impeller, heat-dissipation shaft sleeves

GY6-51 Series

400°C

High Volume & Head

Utility boilers & CFB fluidized-bed systems

Heavy-gauge steel housing, direct/coupling drive

 

Thermal Protection & Mechanical Configurations

 

Continuous thermal loading presents specific mechanical challenges, including thermal shaft expansion, bearing overheating, and impeller creep. We integrate targeted thermal management configurations based on system specifications:

 
01
 

Bearing Protection & Shaft Cooling

Heat-Dissipation Discs: Aluminum cooling vanes mounted between the fan casing and bearing pedestal to dissipate shaft heat before reaching the bearing assembly.
Water-Cooled Bearing Housings: Internal water jackets surrounding oil-lubricated bearings to maintain lubricant viscosity during sustained high-temperature service.

 
02
 

High-Temperature Metallurgy

Up to 350°C: High-yield carbon steel construction with heat-resistant surface coatings.
350°C to 550°C: SS304 or SS316L stainless steel impellers to resist thermal oxidation and scaling.
550°C to 800°C: SS310S (2520) or Inconel nickel alloys engineered to maintain yield strength and mitigate mechanical creep under centrifugal stress.

 
03
 

Mechanical Expansion Accommodation

Expansion Joints: Flexible inlet/outlet connectors designed to absorb multi-axis casing movement during thermal cycles.
Floating Bearings: Fixed-and-floating bearing arrangements allowing axial shaft expansion without inducing radial preloads.

Boiler Forced Draft Fans

 

How We Ensure Product Quality
 

Shandong Qiyue Fan Co., Ltd. operates under ISO 9001, ISO 14001, and ISO 45001 certified management systems, with industrial fan lines holding a registered EAEU Declaration of Conformity.

Material & Structural Integrity

Material Traceability: All heat-resistant carbon steels, stainless steels (SS304, SS316L, SS310S), and nickel-based alloys are supplied with mill test certificates to confirm chemical composition and mechanical strength.
Weld Inspection: High-stress impeller welds, blade-to-shroud joints, and hub connections undergo Non-Destructive Testing (PT/UT) to detect surface and internal defects.
Stress Relieving: High-temperature impellers undergo post-weld heat treatment to eliminate internal stresses and prevent thermal deformation during operation.

Dynamic Balancing & Aerodynamic Testing

Precision Dynamic Balancing: All impellers are dynamically balanced to ISO 1940 Grade G2.5 standards to eliminate vibration and protect bearing assemblies.
Performance Validation: Airflow, static pressure development, and power consumption are tested on certified test benches to match engineered performance curves.

Pre-Shipment Factory Acceptance Testing (FAT)

Every high-temperature fan completes a continuous mechanical run test before dispatch:
Vibration Measurement: Real-time vibration velocity is logged across horizontal, vertical, and axial planes.
Thermal & Bearing Baseline: Bearing housing temperature rise and cooling-water flow rates are monitored until thermal equilibrium is verified.
Inspection Report: Each shipment includes dynamic balancing reports, material certificates, and factory run-test records.

 

productcate-527-746
productcate-527-746
productcate-527-746

 

FAQ

 

Q: Which QIYUE fans are used for boiler induced draft?

A: The dedicated boiler ID range includes Y6-30, Y5-47, Y5-48, and Y8-39 / Y9-38. Y4-73, GY5-51, GY6-41, and GY6-51 can also be configured for induced-draft duties according to the system requirement.

Q: Which fan is used after a boiler dust-removal system?

A: The induced-draft fan is installed in the flue-gas exhaust route, and its required airflow and pressure should include the resistance of the boiler, ductwork, dust-removal equipment, and downstream exhaust system.

Q: How is a high-temperature fan different from a standard centrifugal fan?

A: High-temperature service can require different shaft, bearing, heat-dissipation, sealing, and material configurations. The fan is configured according to the actual gas temperature and mechanical operating conditions.

Q: Can the fan be supplied with a shaft heat-dissipation disc?

A: A shaft heat-dissipation disc can be incorporated into high-temperature fan configurations where required by the specified operating temperature and bearing arrangement.

Q: Can a water-cooled bearing housing be supplied?

A: A water-cooled bearing housing can be specified for fan configurations requiring additional bearing heat removal. The required cooling arrangement is determined from the fan temperature and mechanical configuration.

Q: Can you replace an existing boiler fan?

A: Yes. Existing fan model data, nameplate information, drawings, foundation dimensions, duct connections, rotation direction, and operating data can be used to establish the replacement configuration.

Q: What information is required for a boiler fan quotation?

A: Provide the required airflow, pressure, normal and peak gas temperature, boiler or process type, FD/ID duty, gas condition, motor voltage and frequency, installation dimensions, and quantity.

We're known as one of the most reliable boiler & high temperature fans manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy advanced boiler & high temperature fans made in China here from our factory. All customized products are with high quality and competitive price.