High Temperature Industrial Exhaust Fan

High Temperature Industrial Exhaust Fan

The High Temperature Industrial Exhaust Fan is a centrifugal fan for extracting hot and corrosive process gases. It handles gas temperatures from 250°C to 600°C, with the final temperature rating determined by the fan configuration, material and operating conditions.
Send Inquiry
Description

The High Temperature Industrial Exhaust Fan is a centrifugal fan for extracting hot and corrosive process gases. It handles gas temperatures from 250°C to 600°C, with the final temperature rating determined by the fan configuration, material and operating conditions.

 

Key Specifications

 

Parameter

Specification

Fan Type

Centrifugal Exhaust Fan

Operating Temperature

250°C–600°C, depending on configuration

Airflow Capacity

3,000–120,000 m³/h

Static Pressure

Up to 3,500 Pa

Impeller Material

SUS304 / SUS310S / SUS316L / Inconel 600 / Hardox 450

Motor

TEFC, IP55/IP56, Class H, IE3/IE4

Motor Supply

380–690 V, 50/60 Hz

Drive Arrangement

Arrangement 1, 3 or 9

Drive Type

Direct or Belt Drive

 

Heat Protection

 

Extended Shaft: Separates the bearing assembly from the high-temperature gas path to reduce heat transfer.


Cooling Impeller: Dissipates heat around the shaft and bearing area during operation.


Air-Cooling Discs: Increase airflow around the exposed shaft section to reduce heat transfer toward the bearing housing.


External Bearing Arrangement: Positions the bearing assembly outside the hot gas path.

 

Heavy-Duty Construction

 

Reinforced Casing: 6–12 mm carbon or stainless steel plates with external structural reinforcement.


Impeller: Backward-curved or radial blades designed for the specified airflow and pressure.


Shaft: Forged 42CrMo alloy steel shaft with precision machining.


Rotor Assembly: Complete rotor dynamically balanced to ISO 1940 Grade G2.5 before assembly.

 

Applications

Cement & Lime

Kiln exhaust, clinker cooler ventilation and raw mill exhaust.

Metal Processing

Heat-treatment furnaces, annealing lines and induction furnace off-gas.

Power & Incineration

Biomass boiler draft, incinerator flue gas and baghouse systems.

Chemical & Petrochemical

Corrosive vapor, acid mist and thermal oxidizer exhaust.

Industrial Drying

High-temperature exhaust from drying ovens and heating systems.

Furnace Systems

High-temperature exhaust from industrial furnaces and thermal processing equipment.

 

Configuration Options

 

Drive Arrangement: Arrangement 1, 3 or 9

Drive Type: Direct drive or belt drive

Motor: TEFC motor, IP55/IP56, Class H, IE3/IE4

Shaft Seal: Labyrinth, graphite packing or carbon-ring seal

Temperature Monitoring: Bearing temperature RTD

Vibration Monitoring: Vibration transmitter

Pressure Measurement: Differential pressure connection

Condensate Drain: Drain connection

Nitrogen Purge: Purge connection for specified process conditions

 

Quality Control

 

Material Inspection: Steel plates, shafts and major components are checked against specified material grades before fabrication.


Weld Inspection: Critical impeller welds are inspected by PT and UT.


Dimensional Inspection: Casing, impeller, shaft and mounting dimensions are checked against approved drawings.


Rotor Balancing: Complete rotor assemblies are dynamically balanced to ISO 1940 Grade G2.5.


Bearing Check: Bearing installation, lubrication and shaft alignment are inspected before trial operation.


Motor Test: Voltage, current, rotation direction and insulation are checked before shipment.


Running Test: Each assembled fan is run to check vibration, bearing temperature rise, motor current and airflow performance.


Test Documentation: Material certificates, NDT reports, balancing reports and factory test records are available for project orders.

 

Supply Information

 

Item

Specification

MOQ

1 set

Lead Time

20–30 working days

Packaging

Export wooden case / steel frame

Shipping

FCL / LCL

Technical Documents

Datasheet / GA Drawing / Performance Curve

Inspection Documents

MTC / NDT Report / Balancing Report / Test Report

Spare Parts

Bearings / Seals / Wear Parts

OEM

Available

Warranty

12–24 months

 

Request a Fan Selection

 

Provide the following data for fan sizing:

Airflow

M³/h or CFM

Pressure

Static or total pressure

Gas Temperature

Continuous and maximum temperature

Gas Composition

Gas type and density

Particulate Load

Dust or abrasive particle concentration

Power Supply

Voltage and frequency

Operating Duty

Continuous or intermittent operation

Quantity

Required units

 

FAQ

 

Q: Can the fan be supplied with a GA drawing for system integration?

A: Yes. GA drawings can be provided for checking fan dimensions, inlet and outlet positions, mounting arrangement and connection points before production.

Q: Can the fan be manufactured according to customer drawings?

A: Yes. Qiyue can manufacture the fan according to approved customer drawings and project specifications, including dimensional and connection requirements.

Q: Can the fan be supplied as part of a complete exhaust system?

A: Yes. The fan can be specified as part of an industrial exhaust system and matched with related ductwork and process equipment based on the project requirements.

Q: What information is included in the fan technical documentation?

A: Typical project documentation includes the fan datasheet, GA drawing, performance curve, material certificates, inspection records and factory test records.

Q: Can spare parts be ordered separately after the fan is delivered?

A: Yes. Replacement parts such as bearings, seals and wear components can be supplied separately for maintenance and service requirements.

Q: How is the fan prepared for overseas shipment?

A: The fan is prepared for export transportation with protective packaging suitable for handling, loading and long-distance shipment. Packaging can be arranged according to the shipping method and project requirements.

Q: Can the fan be supplied for replacement of an existing industrial exhaust fan?

A: Yes. Existing fan model information, drawings or installation dimensions can be used to match the replacement unit and maintain compatibility with the existing system.

Q: Can Qiyue provide technical support during installation and commissioning?

A: Yes. Technical information and installation-related documentation can be provided to support installation, connection and commissioning of the supplied fan.

Hot Tags: high temperature industrial exhaust fan, China high temperature industrial exhaust fan manufacturers, suppliers, factory, High Pressure Industrial Exhaust Fan, High Temperature Industrial Exhaust Fan, High Volume Industrial Exhaust Fan, Industrial Centrifugal Exhaust Fan, industrial exhaust fans

Send Inquiry