The High Volume Roof Exhaust Fan is a roof-mounted ventilation fan designed for large-span buildings requiring high-capacity air exhaust. It is available in centrifugal and propeller configurations for different airflow and static-pressure requirements.
Key Specifications
|
Parameter |
Specification |
|
Airflow Capacity |
3,000–55,000 CFM / 5,000–93,000 m³/h |
|
Static Pressure |
Up to 750 Pa / 3.0 in. wg |
|
Impeller Diameter |
450–1,400 mm |
|
Motor Power |
0.55–30 kW / 0.75–40 HP |
|
Electrical |
380–480 V, 3 Phase, 50/60 Hz |
|
Operating Temperature |
-20°C to +60°C |
|
Housing |
1.5–3.0 mm Galvanized Steel / Aluminum |
|
Fan Type |
Centrifugal / Propeller, model dependent |
|
Drive |
Direct Drive / Belt Drive |
|
Installation |
Roof Mounted |
Fan Construction & Drive
Fan Wheel: Centrifugal or propeller configuration selected according to the required airflow and static pressure.
Drive: Direct-drive and belt-drive arrangements cover different fan sizes and operating requirements.
Shaft & Bearings: Belt-drive models use a separate shaft and bearing assembly for service access.
Transmission: Belts and pulleys can be inspected or replaced without replacing the complete fan assembly.
Product Features
High Airflow
Large-diameter fan assemblies up to 1,400 mm and motors up to 30 kW provide airflow up to 55,000 CFM for high-volume exhaust duties.
Low Vibration
The rotating assembly is dynamically balanced before operation to reduce imbalance-related vibration and support smoother running.
Easy Servicing
Belt-drive models provide access to belts, pulleys and bearings for inspection and replacement, simplifying routine maintenance.
Roof Compatibility
The fan can be checked against existing or proposed roof systems using:
Roof Opening: Length × width of the roof opening.
Curb: Length × width × height.
Fan Base: Base dimensions and mounting-hole spacing.
Roof Pitch: Roof slope for curb matching.
Replacement Data: Existing fan model, nameplate and installation dimensions.
Power Supply: Voltage, phase and frequency.
GA or installation drawings can be checked against these dimensions before production to confirm fitment.
Applications
Warehouses & Distribution Centers: Heat and stale-air exhaust across large storage areas.
Manufacturing Plants: Removal of process heat, fumes and airborne contaminants.
Production Workshops: High-volume exhaust for open production spaces.
Commercial Buildings: Rooftop mechanical exhaust for large enclosed areas.
Agricultural Buildings: High-volume ventilation for heat and moisture removal.
Customization
|
Item |
Available Options |
|
Air Performance |
Specified airflow and static pressure |
|
Fan Base |
Non-standard base dimensions |
|
Motor |
Power, voltage, phase and frequency |
|
Drive |
Direct drive or belt drive |
|
Housing |
Galvanized steel / Aluminum / Specified material |
|
Roof Curb |
Dimensions and height |
|
Controls |
VFD or specified control interface |
|
Protection |
Bird screen, guard or weather protection |
|
Identification |
Private-label nameplate and packaging |
Why Choose Qiyue Fan
10,500 m² Manufacturing Facility
Qiyue operates a 10,500 m² manufacturing facility for industrial fan production.
70+ Industrial Fan Series
Qiyue offers more than 70 industrial fan series covering different industrial ventilation and exhaust requirements.
700+ Configurations
More than 700 configurations provide different combinations of fan structure, drive, materials and operating requirements.
ISO-Certified Management Systems
Qiyue operates under ISO 9001, ISO 14001 and ISO 45001 management systems covering quality, environmental and occupational health and safety management.
Accessories & Maintenance
Backdraft Damper: Gravity or motorized type to limit reverse airflow during shutdown.
Bird Screen: Helps prevent birds and debris from entering the exhaust opening.
Safety Guard: Protective guard for specified installation conditions.
Roof Curb: Curb assembly matched to the fan base and roof opening.
Maintenance Parts: Belts, pulleys and bearings are available for belt-drive models.
Supply Information
|
Item |
Supply Information |
|
MOQ |
1 Set |
|
Standard Lead Time |
15–20 Working Days |
|
Custom Lead Time |
25–35 Working Days |
|
Sample |
1 Set |
|
Packaging |
Export Carton / Plywood Case |
|
OEM |
Nameplate, Label & Packaging |
|
Spare Parts |
Motor, Belt, Pulley, Bearing, Damper, Screen |
FAQ
Q: What should be included in a roof exhaust fan quotation?
A: A commercial quotation should include the fan model, airflow, static pressure, motor data, electrical configuration, accessories, quantity, packaging and delivery terms.
Q: What documents are normally required for commercial roof fan projects?
A: Common project documents include a product datasheet, performance data, GA drawing, motor datasheet, wiring diagram and installation instructions.
Q: Can roof exhaust fans be supplied for distributor orders?
A: Yes. Distributor orders can be supplied with private-label nameplates, product labels and packaging according to the confirmed OEM requirements.
Q: What information should I provide when requesting a roof exhaust fan quotation?
A: Provide the required airflow, static pressure, electrical supply, quantity, installation location and any project documentation requirements.
Q: How should roof exhaust fans be compared between suppliers?
A: Compare the stated airflow and static pressure together with motor data, fan construction, drive arrangement, supplied documentation and inspection requirements.
Q: What should be checked before approving a roof exhaust fan order?
A: Check the approved model, performance point, motor specification, electrical data, accessories, drawings and commercial order details before production.
Q: Can the fan be supplied with project documentation?
A: Yes. Product and installation documentation can be prepared according to the confirmed project requirements, including drawings, performance information and electrical documents.
Q: How should a replacement roof exhaust fan be specified?
A: Provide the existing fan model or nameplate together with the original installation dimensions and available project documentation for matching.
Hot Tags: high volume roof exhaust fan, China high volume roof exhaust fan manufacturers, suppliers, factory, Axial Roof Exhaust Fan, Direct Drive Roof Exhaust Fan, High Volume Roof Exhaust Fan, Low Profile Roof Exhaust Fan, roof exhaust fans

