Low Profile Roof Exhaust Fan

Low Profile Roof Exhaust Fan

The Low Profile Roof Exhaust Fan is a roof-mounted centrifugal exhaust fan designed for buildings with limited roof clearance, architectural height restrictions or a need to reduce equipment height above the roof.
Send Inquiry
Description

The Low Profile Roof Exhaust Fan is a roof-mounted centrifugal exhaust fan designed for buildings with limited roof clearance, architectural height restrictions or a need to reduce equipment height above the roof.

 

Key Specifications

 

Parameter

Specification

Airflow

500–35,000 CFM / 850–59,465 m³/h

Static Pressure

Up to 3.5 in. wg / 872 Pa

Impeller Diameter

12–54 in. / 305–1,371 mm

Motor Power

1/4–15 HP / 0.18–11 kW

Drive

Direct Drive / Belt Drive

Voltage

115 V / 208–230 V / 460 V / 575 V

Phase

Single-phase / Three-phase

Frequency

50 / 60 Hz

Operating Temperature

-29°C to 60°C; high-temperature options available

Housing

Spun Aluminum / Galvanized Steel

Installation

Roof Mounted

 

Low-Profile Roof Design

 

The low-profile housing reduces the fan height above the roof, making it suitable for buildings with limited rooftop clearance or restrictions on equipment height.


The reduced roof projection also helps limit the visual and physical footprint of rooftop ventilation equipment.

 

Fan Construction

 

Impeller: Backward-curved centrifugal impeller for roof exhaust applications.


Housing: Heavy-gauge spun aluminum or galvanized steel construction.


Drive: Available in direct-drive or belt-drive arrangements to match different fan sizes and operating requirements.


Motor: AC motor options from 1/4 to 15 HP.


Curb Interface: Fan assembly connects directly to the roof curb at the building exhaust opening.

 

Roof Installation & Replacement

 

Roof Opening: Required roof opening dimensions for checking the fan base fit.


Roof Curb: Curb size, height and mounting dimensions for verifying the fan-to-curb connection.


Fan Base: Base dimensions and mounting-hole arrangement matched to the approved installation drawing.


Rooftop Clearance: Available clearance around the fan and discharge area.


Replacement Data: Existing manufacturer, model, nameplate, fan base and curb dimensions; installation photos can be provided for dimensional checking.


Drawing: GA or installation drawings can be supplied for dimensional confirmation before production.

 

Rooftop Protection & Accessories

 

Backdraft Damper: Gravity or motorized damper for limiting reverse airflow when the fan is not operating.


Bird Screen: Galvanized or stainless steel screen for the exhaust opening.


Roof Curb: Prefabricated curb matched to the fan base and roof opening.


Guards: Protective guards where required by the installation.


Disconnect: Disconnect switch for specified electrical installations.

 

Applications

01/

Warehouses & Distribution Centers: Heat and stale-air exhaust.

02/

Manufacturing Plants & Workshops: Process heat, fumes and airborne contaminants.

03/

Commercial & Office Buildings: General building exhaust.

04/

Institutional Buildings: Mechanical exhaust with rooftop height restrictions.

05/

Multi-Story Parking Structures: Vehicle exhaust and heat removal.

06/

Low-Clearance Roofs: Rooftop exhaust where equipment height is limited.

Customization

 

Customization Item

Examples

Fan Performance

Specified airflow and static pressure operating point

Fan Dimensions

Non-standard fan base or overall dimensions

Roof Curb

Curb size, height and mounting dimensions

Discharge Arrangement

Specified discharge direction or rooftop layout

Electrical

Non-standard voltage, phase or frequency

Controls

Specified motor control or control interface

Protection

Bird screen, guards or other specified protection

Identification

Private-label nameplate, labels or packaging marks

 

Supply Information

 

MOQ: 1 set for standard models; 10 sets for OEM orders.


Lead Time: 15–25 working days for standard orders; 25–40 working days for customized orders.


Sample: 1 set for model evaluation and installation verification.


Packaging: Export plywood case or reinforced carton, with protective packing for sample and production orders.


OEM: Private-label nameplates, labels and packaging marks.

 

Spare Parts

Motor

Replacement motor matched to the original fan specification.

Drive Components

Belts, pulleys and related components for belt-drive models.

Damper

Gravity or motorized backdraft damper.

Protection

Replacement bird screens and guards.

Matching

Spare parts are matched by fan model, motor nameplate or original order details.

FAQ

 

Q: What information should I compare when sourcing roof exhaust fans?

A: Compare airflow, static pressure, motor power, fan dimensions, electrical requirements, construction materials and roof connection details.

Q: Can I use this fan for a replacement project?

A: Yes. Replacement orders can be matched using the existing fan model, nameplate data and installation dimensions.

Q: What documents should I request before placing an order?

A: Request the GA drawing, performance data, motor datasheet, wiring diagram and installation instructions for project review.

Q: How do I verify the fan before shipment?

A: Check the ordered model, motor data, dimensions, impeller rotation, electrical operation and specified accessories against the approved order.

Q: What should be included in a commercial fan quotation?

A: A quotation should identify the fan model, airflow, static pressure, motor specification, electrical supply, accessories, quantity and delivery terms.

Q: Can I order spare parts together with the fan?

A: Yes. Common replacement components can be ordered with the fan or supplied for later maintenance.

Q: How should I identify the correct replacement parts?

A: Provide the fan model, motor nameplate or original order information when requesting replacement parts.

Q: What should I check when comparing suppliers?

A: Compare technical compliance, dimensional drawings, inspection records, documentation, lead time, packaging and spare-parts support.

Hot Tags: low profile roof exhaust fan, China low profile roof exhaust fan manufacturers, suppliers, factory, Axial Roof Exhaust Fan, Direct Drive Roof Exhaust Fan, High Volume Roof Exhaust Fan, Low Profile Roof Exhaust Fan, roof exhaust fans

Send Inquiry

Send Inquiry