Direct Drive Roof Exhaust Fan

Direct Drive Roof Exhaust Fan

The Direct Drive Roof Exhaust Fan is a roof-mounted ventilation fan for continuous exhaust in commercial and industrial buildings. The direct-drive motor connects directly to the fan wheel, eliminating belts and pulleys for a compact roof-mounted exhaust arrangement.
Send Inquiry
Description

The Direct Drive Roof Exhaust Fan is a roof-mounted ventilation fan for continuous exhaust in commercial and industrial buildings. The direct-drive motor connects directly to the fan wheel, eliminating belts and pulleys for a compact roof-mounted exhaust arrangement.

 

Key Specifications

 

Parameter

Specification

Airflow

500–25,000 CFM / 850–42,500 m³/h

Static Pressure

Up to 1.5 in. wg / 373 Pa

Fan Wheel Diameter

12–48 in. / 305–1,219 mm

Motor

Single-phase / Three-phase

Motor Voltage

115 V, 208–230 V, 460 V, 575 V

Frequency

50 / 60 Hz

Operating Temperature

-29°C to 60°C

High-Temperature Option

Up to 149°C

Housing

Aluminum / Galvanized Steel / SS304 / SS316

Discharge

Up-blast / Down-blast

Drive

Direct Drive

 

Roof Installation

 

Curb Connection: Confirm fan base dimensions and curb dimensions against the approved installation drawing.


Roof Opening: Match the curb opening to the existing or planned roof opening before installation.


Discharge Direction: Up-blast discharges air vertically above the roof; down-blast discharges air downward around the curb.


Replacement Projects: Provide the existing fan model, base dimensions, curb dimensions and roof opening for dimensional matching.


Roof Curb: Galvanized steel roof curbs can be supplied for new installations.

 

Fan Construction

 

01/

Fan Wheel: Backward-inclined or airfoil centrifugal wheel, statically and dynamically balanced.

02/

Housing: Heavy-gauge spun aluminum or galvanized steel; SS304 and SS316 are available.

03/

Drive Assembly: Direct-drive motor connects directly to the fan wheel without belts or pulleys.

04/

Curb Cap: One-piece spun cap provides the connection between the fan and roof curb.

05/

Screens: Galvanized or stainless steel bird/insect screens can be fitted at the discharge.

 

Airflow & Operating Performance

 

The fan delivers airflow from 500 to 25,000 CFM (850–42,500 m³/h) against system static pressure up to 1.5 in. wg (373 Pa). Its operating performance is determined by the relationship between airflow and static pressure at the actual system operating point.


Performance data can be provided to verify airflow and static pressure requirements under the specified operating conditions.

 

Outdoor Construction

 

Housing Materials: Aluminum, galvanized steel, SS304 or SS316 can be specified according to the installation environment.


Discharge Screen: Galvanized or stainless steel screens can be used at the discharge opening.


Backdraft Control: Gravity or motorized backdraft dampers can be specified where reverse airflow must be controlled when the fan is stopped.


Temperature: Standard operating temperature is -29°C to 60°C; high-temperature configurations are available up to 149°C.

 

Applications

 

Manufacturing Facilities

General building exhaust and removal of process heat.

Warehouses & Logistics Centers

Roof-level exhaust for heat and stagnant air.

Commercial Buildings

General building ventilation and exhaust.

Industrial Facilities

Exhaust of heated or contaminated building air where the fan specification is suitable.

 

Inspection & Documentation

 

Each completed fan is inspected against the confirmed order and technical drawing before shipment.


Fan Wheel & Rotation: Inspect blade installation, wheel clearance and fastener tightness, then run the fan to confirm correct rotation without blade interference or abnormal contact.


Motor Data: Check motor model, power, voltage, phase and frequency against the confirmed order and nameplate.


Dimensions & Curb Connection: Measure the fan base, outlet, mounting dimensions and curb connection against the approved drawing.


Electrical Operation: Check motor starting, wiring and running current during operation and record the measured current.


Balance & Vibration: Run the assembled fan at operating speed and check for abnormal vibration or rotating imbalance.


Final Assembly: Check fasteners, guards, screens, dampers and other specified components before packing.


Documentation: GA drawing, performance data, motor datasheet, wiring diagram, installation instructions, O&M manual and applicable inspection records can be supplied with the confirmed order.

 

Supply Information

 

MOQ: 1 set for standard orders; OEM orders from 10 sets.

Lead Time: 15–25 working days for standard orders; 25–40 working days for OEM orders.

Packaging: Export plywood case or reinforced carton with protective film.

Spare Parts: Motors, screens, dampers and other specified replacement parts can be supplied.

OEM: Nameplates, labels and packaging marks can be prepared for private-label orders.

 

 

RFQ Information

 

For quotation and technical confirmation, provide:

Required airflow: CFM or m³/h

Required static pressure: In. wg or Pa

Motor power supply: Voltage / phase / frequency

Discharge: Up-blast or down-blast

Roof opening and curb dimensions

Existing fan model, nameplate and installation dimensions for replacement

Operating air temperature and any requirement above 60°C

Required accessories: Backdraft damper, bird/insect screen, roof curb or disconnect switch

Quantity and installation location

 

FAQ

 

Q: What is a direct drive roof exhaust fan?

A: A direct drive roof exhaust fan uses a motor connected directly to the fan wheel, without a belt-and-pulley transmission system.

Q: What is the difference between a direct drive and belt drive exhaust fan?

A: Direct drive removes belts, pulleys and related belt-tensioning components, while belt drive uses a separate belt transmission between the motor and fan wheel.

Q: How do I calculate the required roof exhaust fan airflow?

A: Calculate the required building air changes or exhaust volume in CFM or m³/h, then verify the required airflow against the system static pressure.

Q: What static pressure should I use when choosing a roof exhaust fan?

A: Use the total resistance of the connected ductwork, dampers, filters, louvers and other system components at the required operating airflow.

Q: Can a roof exhaust fan replace an existing fan?

A: Yes. Replacement orders should use the existing fan's model, nameplate and installation dimensions to match the replacement fan and roof connection.

Q: What information should be checked before replacing a roof exhaust fan?

A: Check the existing fan's airflow duty, motor power supply, discharge direction, base and curb dimensions, roof opening and connected duct arrangement.

Q: Does a roof exhaust fan require a roof curb?

A: A roof curb provides the mounting and transition interface between the roof opening and fan. The curb dimensions should match the fan base and roof opening.

Q: What maintenance does a direct drive roof exhaust fan require?

A: Maintenance mainly includes checking the motor, fan wheel, fasteners, screens, dampers and electrical connections, together with periodic inspection for abnormal noise or vibration.

Q: What causes abnormal vibration in a roof exhaust fan?

A: Common causes include fan-wheel imbalance, loose fasteners, installation misalignment, damaged rotating components or motor-related problems

Hot Tags: direct drive roof exhaust fan, China direct drive roof exhaust fan manufacturers, suppliers, factory, Axial Roof Exhaust Fan, Direct Drive Roof Exhaust Fan, High Volume Roof Exhaust Fan, Low Profile Roof Exhaust Fan, roof exhaust fans